020 7864 7245 [email protected] WhatsApp
Glossary

SAP calculations and proving Part L compliance in London

Standard Assessment Procedure — the government's energy-efficiency calculation for dwellings.

Architectural detail on a London period property — architectural drawings in London
In short

SAP — the Standard Assessment Procedure — is the government's methodology for assessing the energy performance of dwellings. A SAP calculation is required for every new dwelling, including those created by conversion, and produces both the compliance check against Part L and the EPC.

Does a house extension need a SAP calculation?

Usually not. An extension normally complies through the elemental route — meeting a limiting U-value for each new thermal element. A SAP calculation is required for a new dwelling, a conversion that creates one, and for an extension that relies on the whole-dwelling calculation route to justify extra glazing.

ElementLimiting U-value, new thermal elementRoute
External wall0.18 W/m²KElemental
Pitched or flat roof0.15 W/m²KElemental
Ground floor0.18 W/m²KElemental
Windows, doors and rooflights1.4 W/m²KElemental
Glazing area in an extension25% of the new floor area, plus openings closed upElemental
New dwelling or conversionwhole-dwelling calculationSAP

Source: Approved Document L, Volume 1: Dwellings (2021 edition, incorporating the 2023 amendments), read at 1 September 2026 — the limiting values for new thermal elements in an existing dwelling and the glazing allowance for extensions. SAP is the Standard Assessment Procedure published by the Department for Energy Security and Net Zero; exceeding the glazing allowance is the commonest reason an extension is pushed onto the calculation route.

When is a SAP needed?

For any new dwelling, and for a dwelling created by material change of use — converting a house into flats, or an outbuilding into a self-contained unit. Extensions to existing dwellings normally use the elemental U-value route instead and need no SAP at all.

The exception is a large glazed extension. Where the glazing exceeds 25% of the extension's floor area plus displaced openings, compliance is shown by calculation, and that calculation is SAP-based.

What are design and as-built SAP?

Design stage SAP is produced from the drawings and specification before construction, and demonstrates compliance for the building control submission. As-built SAP is updated with what was actually installed and with the air test result, and generates the EPC lodged on the register.

Gaps between the two are the common problem: a specified triple-glazed unit substituted for double, or a heat pump swapped for a boiler, and the as-built SAP fails.

What drives the result?

Fabric U-values, thermal bridging, air permeability, the heating system efficiency and controls, hot water storage, ventilation type, and any renewable generation. Thermal bridging is the most commonly underestimated input — using default psi values rather than accredited construction details can cost several SAP points.

What does sap calculation mean for a London project?

How sap calculation plays out in Hammersmith and Fulham: London Borough of Hammersmith and Fulham (Hammersmith & Fulham Council) maintains 45 conservation areas, the Hammersmith Grove Conservation Area and the Brackenbury Village Conservation Area among them, and an Article 4 direction is in force there, so permitted development cannot be assumed. Anyone dealing with sap calculation at a Hammersmith and Fulham address is therefore working to a £548 householder application decided in 8 weeks, or a £249 prior approval over 6 weeks where sap calculation still qualifies.

SAP calculation at a glance

Key figures for SAP calculation
Required forNew dwellings and dwellings created by conversion
Not required forMost extensions
StagesDesign stage and as-built
ProducesPart L compliance and the EPC
Existing homes useRdSAP, a reduced-data version
Key inputsU-values, thermal bridging, airtightness, heating

Common questions about sap calculation

Do I need SAP for an extension?

Usually not — the elemental U-value route applies. A heavily glazed extension may need one.

What is RdSAP?

The reduced-data version used to produce EPCs for existing homes.

Who produces it?

An accredited on-construction domestic energy assessor.

SAP calculation in London — the exterior of London house before works
The exterior of a london house before works — sap calculation in London.
Book a call

Speak to a chartered technologist — free 15 minutes

Pick a slot that suits you. No obligation and no sales pressure, just straight answers on your planning route.

Need help with SAP calculation?

Talk to our MCIAT teamOr contact us about your project first
Structural calculations for a house extension — beam load and bending moment diagrams beside a steel section table — sap calculation in London
Calculations by our in-house structural engineer — beam sizes and load paths settled before your builder prices the job.

Found this useful? Share it

Copies the headline and the link, ready to paste anywhere — helpful if you are planning an extension with a neighbour, builder or architect.

Free quote in 60 seconds
Call us Free quote →

Before you go…

Get a free, no-obligation quote for your project. MCIAT chartered.

council-ready drawing review · All 33 London boroughs