U-values and the insulation London building work needs

Heat transfer coefficient. Lower = better insulation.

Architectural planning drawings for a London project — architectural drawings in London
In short

A U-value is the rate of heat loss through a building element, in watts per square metre per degree kelvin (W/m²K). Lower is better. Approved Document L sets maximum U-values for new thermal elements in an extension: 0.18 for walls and floors, 0.16 for a pitched roof, and 1.4 for windows and doors.

What U-values do real constructions achieve?

An uninsulated solid 215 mm brick wall is around 2.1 W/m²K. An unfilled 1930s cavity wall is about 1.5. A filled cavity is roughly 0.5. A modern extension wall with 100 mm of PIR in the cavity reaches 0.18. Single glazing is about 5.0; standard double glazing about 1.6; a good modern double-glazed unit 1.2 or better.

That range is why a Victorian terrace loses so much through its walls, and why wall insulation is the biggest single fabric improvement available — and also the most disruptive.

New element or existing?

New thermal elements in an extension must meet the new-build standards. Existing elements being renovated have less demanding threshold values — 0.30 W/m²K for a wall, 0.18 for a pitched roof at ceiling level — and even those can be relaxed where the measure is not technically or functionally feasible or the payback exceeds fifteen years.

How is it calculated?

By summing the thermal resistances of every layer in the build-up, including internal and external surface resistances, and taking the reciprocal. Repeating thermal bridges such as timber studs or joists are accounted for using the combined method in BS EN ISO 6946, which is why 100 mm of insulation between studs does not deliver the figure the insulation datasheet suggests.

What does u-value mean for a London project?

How u-value plays out in Harrow: London Borough of Harrow (Harrow Council) maintains 29 conservation areas, the Harrow on the Hill Conservation Area and the Pinner Village Conservation Area among them, and there is no borough-wide Article 4 direction, so permitted development generally survives outside conservation areas. Anyone dealing with u-value at a Harrow address is therefore working to a £548 householder application decided in 8 weeks, or a £249 prior approval over 6 weeks where u-value still qualifies.

U-value at a glance

Key figures for U-value
UnitW/m²K — lower is better
New wall in an extension0.18
Pitched roof at ceiling level0.16
Floor0.18
Window or door1.4
Existing wall on renovation0.30 threshold value

Common questions about u-value

What U-value does my extension wall need?

0.18 W/m²K as a new thermal element.

Do I have to insulate my existing solid walls?

Only when renovating them, and feasibility and payback tests can relax the standard.

Why does my wall not achieve the datasheet figure?

Repeating thermal bridges through studs or joists reduce the effective performance.

U-value in London — the exterior of London house before works
The exterior of a london house before works — u-value in London.
Book a call

Speak to a chartered technologist — free 15 minutes

Pick a slot that suits you. No obligation and no sales pressure, just straight answers on your planning route.

Need help with U-value?

Talk to our MCIAT teamOr contact us about your project first
An architectural technologist checking a printed set of house drawings, marking a proposed elevation in red — u-value in London
Every set is checked line by line against the validation checklist before it leaves the office.

Found this useful? Share it

Copies the headline and the link, ready to paste anywhere — helpful if you are planning an extension with a neighbour, builder or architect.

Free quote in 60 seconds
Call us Free quote →

Before you go…

Get a free, no-obligation quote for your project. MCIAT chartered.

council-ready drawing review · All 33 London boroughs