Air source heat pumps and London planning permission

Renewable heating drawing energy from outside air. Increasingly common in new and retrofit projects.

London terraced street — typical residential housing for architectural drawings in London
In short

An air source heat pump extracts low-grade heat from outside air and raises it to a useful temperature for radiators, underfloor heating and hot water. A well-designed domestic unit delivers a seasonal coefficient of performance around 3.0 to 3.5, so it produces roughly three units of heat per unit of electricity.

Does an air source heat pump need planning permission?

Usually not. An air source heat pump on a house is permitted development under Part 14, Class G, provided it meets the siting and noise conditions and is used solely for heating. The binding one is noise: the installation must meet the MCS planning standard at the nearest neighbouring window.

ConditionRequirementSource
Noise at the nearest habitable room window42 dB(A) assessed under MCS 020GPDO Part 14, Class G
Usesolely for heating the buildingGPDO Part 14, Class G
Sitingnot on a pitched roof, and not above the highest part of the roofGPDO Part 14, Class G
On a wall or roof fronting a highway in a conservation areanot permitted developmentGPDO Part 14, Class G
On a listed buildinglisted building consent requiredPlanning (Listed Buildings) Act 1990
Building regulationsnotifiable work; Part L applies to the systemBuilding Regulations 2010

Source: Town and Country Planning (General Permitted Development) (England) Order 2015, Schedule 2, Part 14, Class G, as amended, together with MCS 020 (the Microgeneration Certification Scheme planning standard for noise), read at 1 September 2026. The siting conditions in Class G have been amended more than once in recent years, so confirm the current text against legislation.gov.uk before relying on a specific clearance distance or volume limit.

Does an air source heat pump need planning permission?

Usually not. Class G of Part 14 of the GPDO permits one ASHP on a house subject to conditions: the unit must comply with MCS Planning Standards, be sited to minimise its effect on amenity, be removed when no longer needed, and it cannot be installed on a pitched roof or within a listed building's curtilage without consent.

On a flat in a conservation area, or where a wall facing a highway is involved, the permitted right is narrower and an application is often the honest route.

What has to change inside the house?

Heat pumps run at 35 to 50 °C flow temperature rather than the 70 to 80 °C a gas boiler uses, so emitters are resized. In a typical London Victorian terrace that means larger radiators in most rooms and a hot water cylinder where a combi boiler previously served instantaneous hot water.

Fabric matters more than the unit. Loft insulation to 270 mm, draught sealing and improved glazing all reduce the heat loss the pump has to meet, which reduces both the capital cost and the running cost.

How does it show up in the building regulations submission?

The installation is notifiable work under Part L and Part G, and the heat loss calculation, emitter schedule and cylinder specification form part of the package. Noise is assessed against the MCS 020 planning standard, which sets a 35 dB(A) limit at the nearest habitable-room window.

What does air source heat pump (ashp) mean for a London project?

How air source heat pump (ashp) plays out in Kingston upon Thames: Royal Borough of Kingston upon Thames (Kingston Council) maintains 22 conservation areas, the Kingston Old Town Conservation Area and the Surbiton Conservation Area among them, and there is no borough-wide Article 4 direction, so permitted development generally survives outside conservation areas. Anyone dealing with air source heat pump (ashp) at a Kingston upon Thames address is therefore working to a £548 householder application decided in 8 weeks, or a £249 prior approval over 6 weeks where air source heat pump (ashp) still qualifies.

Air source heat pump (ASHP) at a glance

Key figures for Air source heat pump (ASHP)
Typical seasonal CoP3.0–3.5
Flow temperature35–50 °C
Permitted development classGPDO Part 14, Class G
Noise limit (MCS 020)42 dB(A) at 1 m from neighbouring habitable window
CylinderRequired; typically 180–250 litres
Loft insulation target270 mm mineral wool

Common questions about air source heat pump (ashp)

Will a heat pump work in a Victorian terrace?

Yes, provided the heat loss is calculated room by room and emitters are resized. Solid walls raise the heat loss but do not rule it out.

Do I need permission in a conservation area?

Often yes, particularly where the unit would be visible from a highway.

Is a heat pump noisy?

A compliant installation is limited to 42 dB(A) at a neighbouring habitable-room window under MCS 020.

An architectural technologist checking a printed set of house drawings, marking a proposed elevation in red — ashp (air source heat pump) in London
Every set is checked line by line against the validation checklist before it leaves the office.
Book a call

Speak to a chartered technologist — free 15 minutes

Pick a slot that suits you. No obligation and no sales pressure, just straight answers on your planning route.

Need help with ASHP (Air Source Heat Pump)?

Talk to our MCIAT teamOr contact us about your project first
A printed planning application drawing set — proposed elevations, floor plans and the os location plan with the site outlined in red — ashp (air source heat pump) in London
The planning set that goes to the council through the Planning Portal: proposed elevations, plans, and the OS location plan with your site outlined.