A conservatory is an extension in planning law, so it needs no planning permission if it fits Class A: 3m deep on a terraced or semi-detached house, 4m if detached, and no more than 4m high. Separately, it avoids building regulations only if it is at ground level, under 30 square metres, and thermally separated from the house.
Checked against the GPDO text on legislation.gov.uk (amendments to 9 April 2026) on 12 September 2026.
It follows exactly the same rules as any other extension to a house. Class A of Schedule 2, Part 1 of the Town and Country Planning (General Permitted Development) (England) Order 2015 either covers it or it does not.
The Planning Portal states that a conservatory 'falls within the same set of planning rules as any other home extension'. A fully glazed structure gets no extra allowance for being lightweight. It is measured, tested and counted towards the 50% ground coverage limit like a brick kitchen extension.
| Class A limit | Terraced or semi-detached | Detached | Reference |
|---|---|---|---|
| Depth beyond the original rear wall | 3m | 4m | A.1(f)(i) |
| Depth with larger home extension prior approval | 6m | 8m | A.1(g)(i) |
| Maximum height | 4m | 4m | A.1(f)(ii) |
| Eaves within 2m of a boundary | 3m | 3m | A.1(i) |
| Side conservatory width | half the original house | half the original house | A.1(j)(iii) |
| Ground covered by extensions and outbuildings | 50% of the curtilage | 50% | A.1(b) |
Sources: GPDO 2015, Schedule 2, Part 1, Class A and Planning Portal: conservatories, retrieved 12 September 2026.
One thing. The materials condition in paragraph A.3(a) does not apply to a conservatory.
For other Class A extensions, exterior materials must look similar to the existing house. A.3(a) exempts materials used in the construction of a conservatory, which is why a white uPVC and glass structure can be permitted development on a London stock-brick terrace when a rendered extension of the same shape might not be.
Everything else is the same. A conservatory forward of the front wall, or on a side wall facing a road, is excluded by A.1(e). One on a flat, a house created by a change of use under Part 3, or a house whose rights were removed by condition or an Article 4 direction needs a householder application. In a conservation area, a side conservatory is not permitted development at all, and the 6m or 8m prior approval route is closed. If you want a deeper rear conservatory outside those areas, the larger home extension prior approval process applies to it.


An exempt conservatory within Class A needs no application. A larger one, or one opened up to the kitchen, needs planning drawings, a building regulations set, or both. The estimator gives an indicative design fee from the floor area.

Yes, if it passes every part of the exemption test. Fail one and it is treated as an extension needing building control approval.
The legal exemption is Class 7 of Schedule 2 to the Building Regulations 2010: a conservatory added at ground level with a floor area of 30 square metres or less, whose glazing meets the safety glazing requirements in Part K. The Planning Portal adds the conditions that keep it an unheated, separate space for energy purposes.
| Exemption test | Pass if | Source |
|---|---|---|
| Position | built at ground level, single storey | BR 2010 Sch. 2, Class 7; Planning Portal |
| Floor area | 30 square metres or less | BR 2010 Sch. 2, Class 7 |
| Separation | external-quality walls, doors or windows between it and the house stay in place | Planning Portal |
| Heating | independent system with separate temperature and on/off controls, or none | Planning Portal |
| Glazing | meets Part K safety glazing requirements | BR 2010 Sch. 2, Class 7 |
| Electrics | fixed installations comply with the regulations | Planning Portal |
Sources: The Building Regulations 2010, Schedule 2 and Planning Portal: conservatories and building regulations, retrieved 12 September 2026.
The test most people fail is separation. Taking out the back doors to make one open kitchen and conservatory removes the thermal barrier, and the conservatory becomes a habitable extension. It then has to meet Part L insulation standards, which a mostly glazed structure struggles to meet. Any new or enlarged structural opening between the house and the conservatory needs building regulations approval in its own right, even if the conservatory stays exempt.
Extending the house heating into the conservatory is the other common failure. A radiator on the main system without its own controls breaks the heating condition.
The planning answer is the same for both, so the choice comes down to building regulations and use. An exempt conservatory costs nothing in building control fees but must stay separated from the house by doors. An extension of the same footprint needs building control approval, but it can open fully into the kitchen and be used all year.
| Exempt conservatory | Single storey extension | |
|---|---|---|
| Planning limits | Class A (3m, 4m high) | Class A (3m, 4m high) |
| Materials condition | does not apply | must look similar to the house |
| Building regulations | exempt at 30 square metres or less if separated | approval needed |
| Open plan to the kitchen | no, unless it loses the exemption | yes |
| Planning application if outside Class A | £548 | £548 |
| Certificate of lawfulness (proposed) | £274 | £274 |
Fees: MHCLG, Planning fees: annual indexation from 1 April 2026, retrieved 12 September 2026.
If a conservatory needs a planning application, the odds are good. English councils granted 90% of the 151,900 householder applications decided in the year to March 2026 (MHCLG, retrieved 12 September 2026). For the full extension limits, read the single storey extension planning guide.
3m deep on a terraced or semi-detached house, or 4m if detached, and no more than 4m high. Within 2m of a boundary, the eaves must be no higher than 3m. The 6m and 8m prior approval limits also apply to conservatories.
No. Paragraph A.3(a) of Class A exempts conservatory materials from the similar-appearance condition that applies to other extensions.
When it is over 30 square metres, not at ground level, open to the house without external-quality doors, heated from the main system without separate controls, or glazed below Part K standards.
Only with building regulations approval. Removing them ends the exemption, and the conservatory must then meet the energy standards for an extension.
Yes. Flats have no Class A permitted development rights.

The planning limits, the building regulations exemption and the fees were read from the primary sources on 12 September 2026. Your council can remove Class A rights by condition or Article 4 direction.