Damp-proof courses in London's older brick housing stock

A barrier preventing rising damp. New extensions must tie into existing DPC level.

Chartered architectural technologist at work — architectural drawings in London
In short

A damp-proof course is a continuous impervious layer built into a wall to stop ground moisture rising through the masonry. Approved Document C requires it to sit at least 150 mm above finished external ground level and to link continuously with the damp-proof membrane in the floor.

How high must a damp-proof course sit?

At least 150mm above the finished external ground level. That single dimension decides more London extension details than any other in Approved Document C, because a new patio or a raised threshold can bridge an existing course and produce damp where none existed.

RequirementDimensionSource
Damp-proof course above external groundat least 150mmApproved Document C
Cavity tray over an opening or abutmentrequired wherever the cavity is bridgedApproved Document C
Ground-supported floor damp-proof membranecontinuous with the wall DPCApproved Document C
Ground floor, new thermal element0.18 W/m²KApproved Document L, Volume 1
Sub-floor ventilation, suspended timber floorcross-ventilated voidApproved Document C
Full plans decision period5 weeks, or 2 months by agreementBuilding Regulations 2010, reg 14

Sources: Approved Document C (site preparation and resistance to contaminants and moisture, 2004 edition incorporating later amendments); Approved Document L, Volume 1 (2021 edition); the Building Regulations 2010 (as amended). Read at 1 September 2026. On London’s Victorian stock the original course is often slate, and a level-threshold extension is the point at which it is most commonly bridged.

What does the regulation actually require?

Part C of the Building Regulations requires walls to resist moisture from the ground. The Approved Document route is a damp-proof course of bituminous felt, polyethylene or engineering brick, positioned a minimum of 150 mm above the adjoining external ground, continuous with the floor's damp-proof membrane so there is no break at the wall-to-floor junction.

Where an extension floor is lower than the existing, or where a patio has been laid over the original DPC, the level is the first thing an inspector checks. Bridging is the single most common cause of damp in a London extension.

What bridges a DPC?

Raised external ground and paving, render carried down past the DPC line, mortar droppings in the cavity, a plaster coat run continuously from wall to floor, and an abutting extension slab poured above the existing DPC. Each provides a capillary path around the barrier.

On a solid-wall Victorian house with no original DPC, the modern approach is usually managing moisture rather than injecting a chemical course: improving external ground levels, removing cement render, and using a breathable internal finish.

How is it shown on the drawings?

The construction section should show the DPC position relative to external ground and to the floor DPM, the cavity tray over any opening, the weep holes at 900 mm centres above the tray, and the vertical DPC at reveals. These are the details building control inspects at damp-proof course stage.

What does damp-proof course (dpc) mean for a London project?

Damp-proof course (DPC) in a Enfield context: London Borough of Enfield (Enfield Council) runs 22 conservation areas including the Forty Hill Conservation Area and the Enfield Town Conservation Area, and there is no borough-wide Article 4 direction, so permitted development generally survives outside conservation areas. That decides how damp-proof course (dpc) is handled: £548 and 8 weeks for a Enfield householder application, or £274 for the Lawful Development Certificate that records damp-proof course (dpc) as lawful. The law behind damp-proof course (dpc) sits in the Town and Country Planning Act 1990, the GPDO 2015 and the Building Regulations 2010.

Damp-proof course (DPC) at a glance

Key figures for Damp-proof course (DPC)
Minimum height above ground150 mm
Governing documentApproved Document C
Common materialsBitumen felt, polyethylene, engineering brick
Weep hole spacing900 mm centres above cavity trays
Must link toFloor damp-proof membrane
Inspection stageDPC and oversite

Common questions about damp-proof course (dpc)

Why is my new extension damp at the base?

Most often the DPC is bridged by external ground level, render or the new slab.

Does a Victorian house have a DPC?

Sometimes a slate course. Many have none, and are managed by ventilation and breathable finishes instead.

Is chemical injection a fix?

It treats one symptom. Ground levels and impermeable finishes are usually the real cause.

An architectural technologist checking a printed set of house drawings, marking a proposed elevation in red — damp-proof course (dpc) in London
Every set is checked line by line against the validation checklist before it leaves the office.
Book a call

Speak to a chartered technologist — free 15 minutes

Pick a slot that suits you. No obligation and no sales pressure, just straight answers on your planning route.

Need help with Damp-proof course (DPC)?

Talk to our MCIAT teamOr contact us about your project first
Damp-proof course (DPC) in London — a London terraced street of the type we survey
A london terraced street of the type we survey — damp-proof course (dpc) in London.

Found this useful? Share it

Copies the headline and the link, ready to paste anywhere — helpful if you are planning an extension with a neighbour, builder or architect.

Free quote in 60 seconds
Call us Free quote →

Before you go…

Get a free, no-obligation quote for your project. MCIAT chartered.

council-ready drawing review · All 33 London boroughs