Measured surveys throughout Camden: floor plans, elevations and sections at ±3mm accuracy. Leica Disto laser plus BLK360 point-cloud capture; AutoCAD and Revit files out; MCIAT chartered technologists drawing them.
Because Camden takes longer than anywhere to decide and negotiates hard: 73.8% of householder decisions inside eight weeks, 17.2% beyond thirteen, and an agreed extension of time on 46.5% of all applications. A drawing error here costs months, not weeks.
| Measure | Camden | London |
|---|---|---|
| Decided inside eight weeks | 73.8% | — |
| Decided beyond thirteen weeks | 17.2% | — |
| Applications with an agreed extension of time | 46.5% | 34.5% |
| Applications withdrawn before decision | 16.8% | 7.4% |
| Listed buildings in the register | 1,967 | — |
| Conservation areas | 40 covering 1,142 ha | 1,141 across London |
| Measured survey, floor plans from | £245 | our fixed fee |
Sources: decision figures from MHCLG District Planning Application Statistics (PS1 and PS2), twelve quarters to March 2026; register counts from the MHCLG Planning Data Platform, retrieved 1 September 2026; the survey fee is our own published fixed fee. Open Government Licence v3.0. Camden’s 1,967 listed buildings are the third highest count in London, so a survey here frequently has to record historic fabric as well as dimensions.
A measured building survey package in Camden, where the stock is largely Victorian and Edwardian terraces, is the full measured-survey-to-submission drawing set London Borough of Camden needs in order to determine an application: existing and proposed plans, elevations and sections at 1:100 and 1:50, a location and site plan, and the supporting statements the case officer asks for.
Prepared and reviewed by the chartered technologist team at Architectural Drawings London — MCIAT chartered, £2m PI insured.Last reviewed 2026-08-03.


Measured surveys across Camden — floor plans, elevations and sections to ±3mm accuracy. Leica Disto laser + BLK360 point-cloud scanning, AutoCAD and Revit deliverables, MCIAT chartered.
Housing stock in Camden: Victorian and Edwardian terraces, Georgian townhouses in Bloomsbury and Hampstead, post-war mansion blocks, modern developments in King's Cross.
Character: Creative, affluent in Hampstead and Primrose Hill; dense mixed-use around Camden Town and Kings Cross; academic character in Bloomsbury.
Article 4: Article 4 removes permitted development for HMO conversions (C3 to C4) across the borough, plus restrictions on basement extensions in 12 conservation areas.
Basement policy: Policy A5 caps a single-storey basement at 50% of the garden area and generally refuses a second storey below ground outside commercial zones. Both of those tests are taken off the existing footprint and garden, which is precisely why the measured survey comes before the design.
One of our chartered technologists attends with a Leica Disto laser and a BLK360. On a two or three bedroom terrace, ninety minutes usually covers it from arrival to packing up.
Revit or AutoCAD, 1:50 or 1:100, everything held to ±3mm. Each room, each opening, each fitting and every service we can see gets annotated while we are still inside the building, so no line on the finished sheet is a guess made afterwards at a desk.
Every elevation, and sections cut right through the building. A Camden planning application draws from those sheets; so does a party wall award, and so does the engineer sizing the steel.
A full point cloud comes off the BLK360, and it earns its keep on Camden stock: 44.7% of the borough's 113,890 dwellings date from before 1900 (VOA CTSOP4.1, at 31 March 2025). On a listed building whose walls bow and whose floors have settled, scanning beats measuring by hand every time.
Deliverables are DWG, RVT, PDF and IFC, so the next hands on the job open the file directly: an architect, the structural engineer, the firm pricing the build.
The set arrives with an RICS-compliant accuracy report: ±3mm point to point, ±5mm absolute across the building. Insurers sign against that document, as do case officers and any party wall surveyor appointed on the job.

Single planning or regs submission.
Planning + building regs + structural.
Listed, conservation, complex sites.
Move the controls for an indicative figure. It anchors your budget — it is not a quote. Every project is priced after a free survey.
Build costs are separate and quoted by your contractor. See our published fees.
The Camden districts we survey in, what each is largely built of, and the authority that validates whatever the survey leads to. Charges listed here are 2026 statutory England rates and sit entirely apart from our survey price.
| Postcode | Area | Dominant stock | What it means for a measured building survey |
|---|---|---|---|
| W1T | Fitzrovia | Georgian terraces, Victorian mansion blocks | W1T straddles a boundary: Fitzrovia addresses fall to Camden Council or Westminster City Council, so confirm which authority validates the measured building survey before submitting W1T drawings. |
| WC1A | Bloomsbury | Victorian and Edwardian terraces | WC1A covers Bloomsbury only; Camden Council handles the measured building survey, and Bloomsbury case officers apply the WC1A conservation-area map. |
| WC1H | Bloomsbury / Cartwright Gardens | Victorian and Edwardian terraces | A measured building survey at an WC1H address in Bloomsbury / Cartwright Gardens is determined by Camden Council under its own Local Plan policies for Bloomsbury / Cartwright Gardens. |
| WC1N | Bloomsbury / Russell Square | Victorian and Edwardian terraces | WC1N covers Bloomsbury / Russell Square only; Camden Council handles the measured building survey, and Bloomsbury / Russell Square case officers apply the WC1N conservation-area map. |
| WC1R | Holborn | Victorian and Edwardian terraces | A measured building survey at an WC1R address in Holborn is determined by Camden Council under its own Local Plan policies for Holborn. |
Ridge heights, wall build-ups and plot depths shift street by street between Bloomsbury and Highgate, and every one of those is a reason to measure a building rather than assume it.
Camden conservation designations: forty of them, with Primrose Hill, Bloomsbury and Camden Town the best known. Inside one, permitted development is off the table, so work goes in on the £548 householder route with an eight-week target instead of a £249 prior approval at six. Hampstead is the designation that redirects a Camden scheme most often, and every application inside it is judged against a drawing of what stands there now.
Camden and Article 4: Article 4 removes permitted development for HMO conversions (C3 to C4) across the borough, plus restrictions on basement extensions in 12 conservation areas. A measured building survey planned at a N1C address is checked against that direction first; Camden Council publishes the Camden extent, and the N1C line rarely follows the Camden boundary you would expect.
Camden below-ground policy: Camden's basement policy (Policy A5) restricts single-storey basements to 50% of garden area; double-storey basements generally refused outside commercial zones. Any measured building survey in Camden that goes below existing foundations triggers two months notice under section 6 of the Party Wall etc. Act 1996, and Camden Council will want the N1C ground and groundwater position set out.
The building fabric around Camden: Victorian and Edwardian terraces, Georgian townhouses in Bloomsbury and Hampstead, post-war mansion blocks, modern developments in King's Cross. Creative, affluent in Hampstead and Primrose Hill; dense mixed-use around Camden Town and Kings Cross; academic character in Bloomsbury. A measured building survey in Camden is scoped against that stock first, because it decides whether the scheme runs as permitted development, a £274 Lawful Development Certificate, or a full £548 application to Camden Council.
Sources for this Camden measured building survey page: borough policies maps and conservation-area registers (2025–26), Royal Mail postcode district boundaries, the Town and Country Planning (Fees for Applications) (England) Regulations, the Town and Country Planning (General Permitted Development) (England) Order 2015 as amended, and the Party Wall etc. Act 1996.
Straight answers to what Camden owners, agents and builders ask us before booking a survey here.
Start a free quote →Cost follows the size and the awkwardness of the building. A two-bed terrace sets the baseline; three-bed semi, four-bed detached and flat conversion each step above it; listed or unusually large properties are priced individually. Plans, elevations and sections sit inside every quote, and an hourly rate never enters into it. See our fees.
Expect an hour to two hours on site according to how big the property is, with drawings back inside 5 working days and a 48-hour option for a small premium. Worth knowing what happens next: 596 of Camden's 1,179 householder decisions, over half the total, were settled under a performance agreement or with the time formally extended, rather than on the statutory eight-week clock (MHCLG planning statistics, retrieved 1 September 2026).
Accuracy is ±3mm point to point. The instruments are a Leica Disto X3 and, for the 3D capture, a BLK360. Output is RICS-compliant and goes through with Camden Council planning, Building Control, structural engineers and party wall surveyors alike.
Yes — Camden's victorian and Edwardian terraces period stock is our core work. We survey listed buildings, conservation area properties and complex geometries using BLK360 point-cloud scanning. The 3D scan captures every architectural detail for heritage statements and planning applications.
Files come back as .dwg, .rvt, PDF and IFC: floor plans, elevations, sections, and the point cloud wherever the property was scanned. All annotated, and ready to hand straight to an engineer or into a Camden submission.
Yes — flats, maisonettes, HMOs and conversions across all Camden postcodes (NW1, NW3, NW5, NW6, WC1, WC1H, WC1N, WC1R, WC1V, WC1X, N6, N7, N19). We handle communal areas, staircases and party walls between dwellings — essential for flat conversion planning applications or lease drawings.
Yes. Camden's validation officers reject submissions whose existing plans will not reconcile with the proposed ones. For a sense of the attrition, 1,026 of the 6,858 applications the borough received in the period were withdrawn before any decision, 15.0% of them, for reasons ranging from officer advice to a scheme that simply did not stack up. An accurate existing set is also the base the building regulations package gets built on.
We cover all Camden postcodes — NW1, NW3, NW5, NW6, WC1, WC1H, WC1N, WC1R, WC1V, WC1X, N6, N7, N19 — and adjacent boroughs. Survey appointments within 3 working days, no travel charges within Greater London.

If your property sits on a boundary, here are the neighbouring options.
Camden served 188 enforcement notices in the three years MHCLG has published to last March, alongside 119 planning contravention notices, 24 breach of condition notices and 6 stop notices (MHCLG planning statistics, retrieved 1 September 2026). The capital issued 3,554 enforcement notices in that time, so one borough out of thirty-three accounted for 5.3% of them. Where a council polices what was actually built that closely, the drawing of what already stands has to be right. One chartered team measures it and draws everything that follows.
A construction-ready drawing package compliant with every Approved Document — Part A structure, Part B fire, Part L thermal, Part M accessib...
Every loft type across every Camden roof line — dormer, mansard, hip-to-gable, L-shape, Velux. LDC or full planning route, building regulati...
The whole spectrum — rear extensions, side returns, wraparounds, double-storey, basement digs. Planning-led design with detailed technical p...
Camden's most space-efficient loft solution when PD-route dormers are blocked. Our chartered team designs mansards that get approved in Camd...
Turn your unused Camden garage into a bedroom, home office or open-plan kitchen-diner. Planning route assessment, full building regulations ...
Full architectural technology service for basement digs and cellar conversions in Camden — structural underpinning design, waterproofing str...
Chartered structural engineer calculations for every residential intervention in Camden — steel beams, lintels, pad foundations, wall remova...
End-to-end Party Wall Act 1996 service for Camden — Section 1, 3 and 6 notices, schedule of condition surveys, party wall award coordination...
London's most popular loft type — the full-width rear dormer. Planning or Permitted Development route assessed for your Camden property, bui...
Leave your number and an Architectural technologist will call you back within 30 minutes during working hours.
No obligation. No sales pressure. Just expert advice about measured building survey in Camden.
Free quote in 60 seconds. No hourly billing. MCIAT chartered.
Get my free quote →