020 7864 7245 [email protected] WhatsApp
Home Tools PD Volume Calculator
Free tool

Is My Loft Conversion Within Permitted Development Limits?

Under Class B of the GPDO, loft additions up to 40m³ (terraced) or 50m³ (detached / semi-detached) can be built without planning permission — if every other Class B rule is also met.

1
Property
2
Dimensions
3
Previous
4
Verdict
Step 1 of 4

How is permitted development roof volume measured?

Against the roof as originally built, not as it stands today. Class B allows 40 cubic metres on a terrace and 50 on a semi or detached house, and any earlier dormer counts against the allowance even if a previous owner built it.

Class B ruleTerraceSemi or detached
Added roof volume allowed40 m³50 m³
Measured againstthe roof as originally builtthe roof as originally built
'Original' meansas first built, or as at 1 July 1948as first built, or as at 1 July 1948
Beyond the front roof planenot permittednot permitted
Above the existing ridgenot permittednot permitted
Set back from the eavesat least 200mmat least 200mm
Inside a conservation areaClass B does not applyClass B does not apply

Source: the Town and Country Planning (General Permitted Development) (England) Order 2015, Schedule 2, Part 1, Class B, as amended, read at 1 September 2026. The allowance is cumulative, which is why a house with an existing dormer often has far less headroom than the calculator's headline figure suggests until the earlier volume is deducted.

What type of property is it?

Your property type determines your Class B volume allowance.

Class B allowance: 40m³ for terraced and end-of-terrace houses; 50m³ for detached and semi-detached houses. Flats and maisonettes are not eligible for loft PD rights under Class B.
Terraced 40m³ limit
End-of-terrace 40m³ limit
Semi-detached 50m³ limit
Detached 50m³ limit
Flat / Maisonette PD not available
Step 2 of 4

Proposed loft addition dimensions

Enter the approximate dimensions of the volume you want to add (e.g. a rear dormer enclosure). For L-shaped or hip-to-gable schemes, measure each segment separately and sum the volumes.

m
m
m
Proposed volume
Step 3 of 4

Has any previous loft or roof addition been made?

Class B allowance is cumulative — any previous loft/roof additions (including by previous owners, since 1948) count against your 40m³/50m³ limit.

Has any previous loft or roof extension been built?

If you're not sure, we measure existing roof additions on survey and calculate the remaining allowance precisely.

0 m³
PD allowance (Class B limit)
Volume already used by previous extensions
Proposed addition volume
Remaining PD allowance after proposed

Recommended next step

Get exact quote →
MCIAT chartered council-ready review

Tell us about your project

MCIAT chartered drawings for planning, building regs, lofts and extensions. Tell us what you need and we’ll reply the same working day.

  • MCIAT chartered
  • Same working-day reply

Found this useful? Share it

Copies the headline and the link, ready to paste anywhere — helpful if you are planning an extension with a neighbour, builder or architect.

Link copied to clipboard
Free quote in 60 seconds
Call us Free quote →

Before you go…

Get a free, no-obligation quote for your project. MCIAT chartered.

council-ready drawing review · All 33 London boroughs